NYC-WTC_000060909
GCMS calibration verification report for sample AE07173 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗GCMS calibration verification report for sample AE06580 showing response factors for organic compounds.
NYC-WTC_000060789–000060795Folder label: “GCMS X 3/25/02 A 4/17/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (Not Reviewed)
Data File : C:\MSDCHEM\1\DATA\0417 0 2\SURAO 417.D Vial: 4 Acq On : 17 Apr 2002 11:00 am Operator: Bohlk Sample : SURROGATE, DDD Inst : Instrumen Mise Multiplr: 1.00 MS Integration Params: BENZO.P . Quant Time: Apr 17 11:45:01 2002 Quant Results File: 5080402BBC.RES
Quant Method : C:\MSDCHEM\l\5973N\5080402BBC.M (RTE Integrator) Title : Quantitation For Method 508gcscan Last Update : Tue Apr 16 18:27:45 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 0.00 152 0 0.00 ug/L -9.41 10) Naphthalene-d8 0.00 136 0 0.00 ug/L -12.89 17) Acenaphthene-dl0 0.00 164 0 0.00 ug/L -17.98 30) Phenanthrene-dl0 0.00 188 0 0.00 ug/L -22.34 39) Chrysene-dl2 0.00 240 0 0.00 ug/L -30.15 45) Perylene-dl2 0.00 264 0 0.00 ug/L -34.01
System Monitoring Compounds 28) TCMX (SURR) 0.00 244 0 0.00 ug/L Spiked Amount 10.000 Recovery = . 0.00% 38) 2,4-DDD (SURR) 27.27 235 137756 0.00 ug/L 0.00 Spiked Amount 10.000 Recovery 0.00%
Target Compounds Qvalue 2) N-nitroso-dimethyl amine 0.00 74 0 N.D. 3) bis (2-chloroethyl) ether 0.00 93 0 N.D. 4) 1,3 Dichlorobenze 0.00 146 0 N.D. 5) 1,4 Dichlorobenzene 0.00 146 0 N.D. 6) 1,2 Dichlorobenzene 0.00 146 0 N.D. 7) 2,2 ' - oxybis (1-Chloropr 0.00 45 0 N.D. 8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D. 9) Hexachloroethane 0.00 117 0 N.D. 11) Nitrobenzene 0.00 77 0 N.D. 12) Isophorone 0.00 82 0 N.D. 13) bis(2-Chloroethoxy) methan 0.00 93 0 N.D. 14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D. 15) Naphthalene 0.00 128 0 N.D. 16) Hexachlorobutadiene 0.00 225 0 N.D. 18) Hexachlorocyclopentadiene 0.00 237 0 N.D. 19) 2-chloronaphthalene 0.00 162 0 N.D. 20) Dimethylphthalate 0.00 163 0 N.D. 21) 2,6-Dinitrotoluene 0.00 165 0 N.D. 22) Acenaphthylene 0.00 152 0 N.D. 23) Acenaphthene 0.00 153 0 N.D. 24) 2,4-Dinitrotoluene 0.00 165 0 N.D. 25) Diethylphthalate 0.00 149 0 N.D. 26) 4-Chlorophenyl-phenyl ethe 0.00 204 0 N.D. 27) Fluorene 0.00 166 0 N.D. 29) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D. 31) N-Nitrosodiphenylamine 0.00 169 0 N.D. 32) 4-Bromophenyl-phenyl ether 0.00 248 0 N.D. 33) Hexachlorobenzene 0.00 284 0 N.D. 34) Phenanthrene 0.00 178 0 N.D. 35) Anthracene 0.00 178 0 N.D. 36) Di-n-butylphthalate 0.00 149 0 N.D. 37) Fluoranthene 0.00 202 0 N.D. 4 0) Pyrene 0.00 202 0 N.D. 41) Butylbenzylphthalate 0.00 149 0 N.D. 42) Benzo (a) antracene 0.00 228 0 N.D. 43) Bis (2-ethylhexyl) phthala 0.00 149 0 N.D. 44) Chrysene 0.00 228 0 N.D.
(#) = qualifier out of range (m) = manual integration SURA0417.D 5080402BBC.M Wed Apr 17 11:45:18 2002 Page 1
NYC-WTC_000060793
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000060909
GCMS calibration verification report for sample AE07173 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060120
Laboratory report documenting GCMS analysis of environmental sample AE06049 conducted on April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060999
Calibration data for gas chromatography mass spectrometry listing response factors for multiple organic analytes.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060340
Laboratory report showing GC/MS calibration verification for Method 508 compounds with measured values.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060576
DEP laboratory report of GCMS calibration analysis for sample AE06800 conducted on April 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061188
Calibration data from gas chromatography mass spectrometry listing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060796
GCMS reference standard analysis report for sample AE06580 showing response factors and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061009
Reference standard analysis report for gas chromatography mass spectrometry quantifying recovery of target compounds.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059990
Detailed laboratory report listing quantitative concentrations of organic compounds detected in sample AE06090.
1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061192
Reference standard analysis report for gas chromatography mass spectrometry quantifying recovery of target analytes.
1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046904
Laboratory report of GCMS analysis for reference standard sample AE07416 showing compound concentrations and qualifiers on April 19, 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039773
Quantitative results for volatile organic compounds in sample AE06585 analyzed on April 15, 2002.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000060909
GCMS calibration verification report for sample AE07173 showing response factors for organic compounds.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060999
Calibration data for gas chromatography mass spectrometry listing response factors for multiple organic analytes.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039773
Quantitative results for volatile organic compounds in sample AE06585 analyzed on April 15, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039770
Surrogate recovery data for compounds including DDD analyzed on April 15, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060120
Laboratory report documenting GCMS analysis of environmental sample AE06049 conducted on April 5, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059981
Detailed laboratory report listing quantitative concentrations of organic compounds detected in sample AE06090.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000060774
Environmental Protection Department record from the World Trade Center site containing a redacted name.
Filed in the same folder
NYC-WTC_000060775
Header page for a GCMS laboratory record showing extraction parameters and drip rate instructions.
Filed in the same folder
NYC-WTC_000060778
Instrument log page for DFTAA417.D analysis using AcqMethod 508SCAN on April 17, 2002.
Filed in the same folder
NYC-WTC_000060780
GCMS blank analysis report for sample AE06580 listing compounds with values below detection limits.
Filed in the same folder
NYC-WTC_000060796
GCMS reference standard analysis report for sample AE06580 showing response factors and detection limits.
Filed in the same folder