NYC-WTC_000060120
Laboratory report documenting GCMS analysis of environmental sample AE06049 conducted on April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗DEP laboratory report of GCMS calibration analysis for sample AE06800 conducted on April 10, 2002.
NYC-WTC_000060576–000060582Folder label: “GCMS X 3/22/02 A 4/7/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (Not Reviewed)
Data File C:\MSDCHEM\l\DATA\040502\SURC0405.D Vial: 37 Acq On 7 Apr 2002 12:24 am Operator: Bohlk Sample SURROGATE Inst : Instrumen Mise Multiplr: 1.00 MS Integration Params: BENZO.P Quant Time: Apr 08 05:33:54 2002 Quant Results File: 5080402.RES
Quant Method : C:\MSDCHEM\l\5973N\5080402.M (RTE Integrator) Title : Quantitation For Method 508gcscan Last Update : Fri Apr 05 05:56:22 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN
Compound R.T. Qlon Response Cone Unit Qvalue
47) Benzo (k) fluoranthene 0.00 252 0 N.D. 48) Benzo (a) pyrene 0.00 252 0 N.D. 49) Indeno (1,2,3-cd) pyrene 0.00 276 0 N.D. 50) Dibenz (a,h) anthracene 0.00 278 0 N.D. 51) Benzo (g,h,i) perylene 0.00 276 0 N.D.
(#) = qualifier out of range (m) = manual integration SURC0405.D 5080402.M Mon Apr 08 05:34:13 2002 Page 2
NYC-WTC_000060581
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000060120
Laboratory report documenting GCMS analysis of environmental sample AE06049 conducted on April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060340
Laboratory report showing GC/MS calibration verification for Method 508 compounds with measured values.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060999
Calibration data for gas chromatography mass spectrometry listing response factors for multiple organic analytes.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060909
GCMS calibration verification report for sample AE07173 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060789
GCMS calibration verification report for sample AE06580 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059981
Detailed laboratory report listing quantitative concentrations of organic compounds detected in sample AE06090.
1 shared topics · Same agency, volume and box · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060127
Laboratory report showing GCMS reference standard analysis for sample AE06049 conducted on April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060796
GCMS reference standard analysis report for sample AE06580 showing response factors and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060583
DEP laboratory report of GCMS reference analysis for sample AE06800 conducted on April 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061009
Reference standard analysis report for gas chromatography mass spectrometry quantifying recovery of target compounds.
1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039909
Laboratory report providing GCMS reference data for sample AE06760 analyzed in April 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039773
Quantitative results for volatile organic compounds in sample AE06585 analyzed on April 15, 2002.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000060561
Environmental Protection Department record from the World Trade Center site dated March 2002.
Filed in the same folder
NYC-WTC_000060562
DEP document outlining laboratory methods, drip rates, and verification signatures for environmental analysis.
Filed in the same folder
NYC-WTC_000060569
DEP laboratory report of GCMS blank analysis for sample AE06800 conducted on April 10, 2002.
Filed in the same folder
NYC-WTC_000060583
DEP laboratory report of GCMS reference analysis for sample AE06800 conducted on April 10, 2002.
Filed in the same folder
NYC-WTC_000060591
DEP laboratory report of GCMS analysis for sample AE05908 conducted on April 12, 2002.
Filed in the same folder