NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\1\DATA\MAR2 6 02\LB.D Vial: 3
Acq On 26 Mar 2002 10:42 am Operator:
Sample gc/ms scan 3/4 Inst : GC/MS 209
Mise Multiplr: 1.00 /
MS Integration Params: GOOFY.P
Quant Time: Mar 28 15:07 2002 Quant Result’s File: GCMS03 08.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0308.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Tue Mar 26 14:13:06 2002
Response via : Initial Calibration
DataAcq Meth : GCMS0308
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 12.25 152 545421 20.00 ug/1 -0.10
10) Naphthalene-d8 15.89 136 2104384 20.00 ug/1 -0.11
17) Acenaphthene-dlO 21.19 164 1153635 20.00 ug/1 -0.12
29) Phenanthrene-dlO 25.64 188 1640096 20.00 ug/1 -0.13
38) Chrysene-dl2 33.70 240 877645 20.00 ug/1 -0.15
44) Perylene-dl2 37.94 264 509204 20.00 ug/1 -0.18 \
System Monitoring Compounds
37) 2,4-DDD 0.00 235 0 I 0.Oo ug/mL
Spiked Amount 5.000 Recovery 0.00%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 0.00 74 0 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 12.16 146 329 N.D.
5) 1,4-Dichlorobenzene 12.30 146 365 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2'-oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 15.78 180 202 N.D.
15) Naphthalene 15.94 128 561 N.D.
16) Hexachlorobutadiene 16.49 225 522 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene O.'OO 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 0.00 165 0 N.D.
25) Diethylphthalate 0.00 149 0 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
LB.D GCMS0308.M Thu Mar 28 15:08:58 2002 Page 1
NYC-WTC_000058353
OCR can misread numbers and units. Confirm readings against the page image before using them.