NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File ; C:\HPCHEM\1\DATA\MAR27O2\4589.D Vial: 12
Acq On : 28 Mar 2002 12:33 am Operator:
Sample : gc/ms scan 3/2 Inst ; GC/MS 209
Mise Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Mar 29 12:49 2002 Quant Results File; GCMS0308.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0308.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Fri Mar 29 10:31:28 2002
Response via : Initial Calibration
DataAcq Meth : GCMS0308
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 12.25 152 749305 20.00 ug/1 -0.10
10) Naphthalene-d8 15.89 136 2920472 20.00 ug/1 -0.11
17) Acenaphthene-dlO 21.20 164 1599258 20.00 ug/1 -0.12
29) Phenanthrene-dlO 25.64 188 2322297 20.00 ug/1 -0.13
38) Chrysene-dl2 33.70 240 1263379 20.00 ug/1 -0.15
44) Perylene-dl2 37.95 264 748619 20.00 ug/1 -0.17
System Monitoring Compounds
37) 2,4-DDD 30.72 235 90589 3.89 ug/mL 0.22
Spiked Amount 5.000 Recovery = 77.80%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 0.00 74 0 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 12.30 146 590 N.D.
5) 1,4-Dichlorobenzene 12.30 146 590 ■ N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2'-oxybi s(1-Chioropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachioroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 15.94 128 604 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
2 3) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 21.58 165 179 N.D.
25) Diethylphthalate 22.67 149 939 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
4589.D GCMS0308.M Fri Mar 29 12:51:06 2002 Page 1
NYC-WTC_000058233
OCR can misread numbers and units. Confirm readings against the page image before using them.