GCMS calibration results for sample AE09334, April 2002

Machine-extracted title · confidence 100%

Laboratory report showing GCMS calibration data for sample AE09334 generated on April 25-26, 2002.

NYC-WTC_000046351–000046359

Folder label: “GCMS X 5/7/02 A 5/9/02

Page image
Scanned page image, NYC-WTC_000046352
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

Data File : C:\HPCHEM\1\DATA\APR2 502\9334.D Vial: 11 Acq On : 25 Apr 2002 10:26 pm Operator: Sample : gc/ms scan 4/18 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: Apr 26 7:47 2002 Quant Results File: GCMS0412.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS0412.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Thu Apr 25 15:21:43 2002 Response via : Initial Calibration DataAcq Meth : GCMS0412

Compound R.T. Qlon Response Cone Unit Qvalue

33) Hexachlorobenzene 0.00 284 0 N.D. 34) Phenanthrene 25.65 178 107 N.D. 35) Anthracene 25.58 178 499 N.D. 36) Di-n-butylphthalate 27.55 149 3078 N.D. 37) Fluoranthene 0.00 202 0 N.D. 40) Pyrene 0.00 202 0 N.D. 41) Butylbenzylphthalate 0.00 149 0 N.D. 42) Benzo(a)anthracene 33.64 228 3120 N.D. 43) Bis(2-ethylhexyl)phthalate 33.86 149 36222 1.06 ug/1 99 44) Chrysene 33.64 228 3121 N.D. 46) Di-n-Octylphthalate 0.00 149 0 N.D. 47) Benzo(b)fluoranthene 0.00 252 0 N.D. 48) Benzo(k)fluoranthene 0.00 252 0 N.D. 4 9) Benzo(a)pyrene 37.87 252 3427 N.D. 50) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 51) Dibenz(a,h)anthracene 0.00 278 0 N.D. 52) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration 9334.D GCMS0412.M Fri Apr 26 07:47:47 2002 Page 2

NYC-WTC_000046352

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000046352Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →