NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 23/GCMS X 3/18/02 A 4/8/02
Document / 10 pages

GCMS analysis results for sample AE06305, April 2002

Machine-extracted title · confidence 100%

Laboratory report documenting GCMS analysis of sample AE06305 conducted on April 17, 2002.

NYC-WTC_000039353–000039362

Folder label: “GCMS X 3/18/02 A 4/8/02

Page image
Scanned page image, NYC-WTC_000039356
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

Data File C:\MSDCHEM\l\DATA\020408\6305.D Vial: 13 Acq On 8 Apr 2002 10:02 pm Operator: McLean Sample 3/18 Inst Instrumen Mise Multiplr: 1.00 MS Integration Params: EVENTS.E Quant Time: Apr 09 15:15:07 2002 Quant Results File: SCANAPR0902.R

Quant Method : C:\MSDCHEM\1...\SCANAPR0902.M (Chemstation Integrator) Title : Method 508 GC/MS Scan Last Update : Tue Apr 09 15:05:54 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN1

Compound R.T. Qlon Response Cone Unit Qvalue

34) Phenanthrene 0.00 178 0 N.D. 35) Anthracene 0.00 178 0 N.D. 36) Di-n-butylphthalate 33.98 149 33075 0.02 ug/1 79 37) Fluoranthene 0.00 202 0 N.D. 4 0) Pyrene 0.00 202 0 N.D. 41) Buthylbenzylphthalate 0.00 149 0 N.D. 42) Benz(a)anthracene 0.00 228 0 N.D. d 43) Chrysene 0.00 228 0 N.D. d 44) Bis(2-ethylhexyl)phthalate 0.00 149 0 N.D. 46) Di-n-Octyl phthalate 0.00 149 0 N.D. 47) Benzo(b)fluoranthene 0.00 252 0 N.D. 48) Benzo(k)fluoranthene 0.00 252 0 N.D. 4 9) Benzo(a)pyrene 0.00 252 0 N.D. d 50) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 51) Dibenz(a,h)anthracene 0.00 278 0 N.D. 52) Benzo(ghi)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration (+) = signals summed 6305.D SCANAPR0902 .M Tue Apr 09 15:15:37 2002 Page 2

NYC-WTC_000039356

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000039356Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →