LSC Area Percent Report

' Data File : C:\HPCHEM\1\DATA\DEC1201\27289.D Vial: 5 Acq On : 12 Dec 2001 6:57 pm Operator: GALOS Sample : gc/ms unknown 11/14 Inst : GC/MS Ins Mise Multiplr: 1.00 MS Integration Params: LSCINT.P

Method : C:\HPCHEM\1\METHODS\NP112701.M (RTE Integrator) Title : 208 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP

If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5

Signal : TIC

peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total

1 7.811 321 324 334 rBV 85533 186777 2.07% 0.415% 2 10.470 610 614 623 rBB 50360 95587 1.06% 0.212% 3 11.837 757 763 779 rBV 3350283 6947796 76.94% 15.432% 4 15.441 1150 1156 1174 rBV 4525139 9030121 100.00% 20.058% 5 20.713 1725 1731 1751 rBV 4252013 8743770 96.83% 19.421%

6 25.124 2205 2212 2224 rBV2 4021872 8249496 91.36% 18.324% 7 33.130 3078 3085 3102 rBV2 2937512 6326749 70.06% 14.053% 8 37.210 3522 3530 3547 rBV2 2030038 5440795 60.25% 12.085%

Sum of corrected areas: 45021091

27289.D NP112701.M Fri Dec 14 10:09:04 2001

NYC-WTC_000032905

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000032905Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →