Quantitation Report Quanfile: 26677H Quan Entries: 16 o
GO
O
Comment: BOHLK; METHOD 525; INST 204; 11/28/01; SANPLE 26677 "0
0
Sorted via: Entry Number T (S) = Standard —
9
U
0
Cal Name of Compound S Scant R Time Ne Calc Amt(A) Units 0
C
3
CD
1 acenaphthene d-10(IS) I 732 12:12 BB 5.008 UG/L —
2 phenanthrene d-10 (IS) I 1008 16:48 BV 5.000 UG/L
3 chrysene d-12(IS) I 1355 22:35 BB 5.000 UG/L
4 p-terphenyl d-14(IS) I 1246 20:46 BV 5.000 UG/L
5 acenaphthene d-10(SURR A 732 12:12 BB 4.287 UG/L
6 phenanthrene d-10(SURR A 1008 16:48 BV 4.509 UG/L
7 chrysene d-12 (SURR) A 1355 22:35 BB 4.104 UG/L
8 1»3-d imethy1-2-n itrobe A 474 7:54 BV 4.987 UG/L
9 triphenyl phosphate (S A 1321 22:01 BB 6.088 UG/L
10 perylene d-12 (SURR) A 1608 26:48 BB 4.662 UG/L
13 simazine A 960 16:80 BB 0.001 UG/L
16 b is (2-ethyIhexy Dad ipa A 1314 21:54 NN 0.047 UG/L
17 b is (2-ethy Ihexy l phtha A 1373 22:53 W 0.516 UG/L
20 2,6-d in itrotoluene A 713 11:53 BB 0.983 UG/L
21 2 j4-d in itrotoluene A 781 13:01 BB 0.095 UG/L
27 butachlor A 1222 20:22 BB 0.001 UG/L
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000030141Source: NYC Law Department, mirrored locally
Laboratory analysis of sample AD24400 for pesticides and organic contaminants using method 525.2, with results measured in micrograms showing all analytes below method detection li