Comments for Sample AD24945 - Analysis $525
Westchester Dept of Labs & Research
User: Vinci, David L
Date: 11-24-2001 Time: 11:55:31
The recovery for 1 of the 3 Surrogate Standards in this sample was below its
acceptance range. Recoveries for 7 of the 18 compounds in the MDL Standard were
outside of their acceptance ranges, with no recovery for Benzo(a)pyrene,
probably due to contamination showing in its chromatographic region. Recoveries
for 6 of the 18 compounds in the LCS Standard were outside of their acceptance
ranges. Recoveries for 2 of the 18 compounds in the Spiked sample and spiked
Duplicate Sample were outside of their acceptance ranges.
NYC-WTC_000029030
OCR can misread numbers and units. Confirm readings against the page image before using them.