NYC 9/11 Public Portal Document
REPORT OF ANALYSIS
Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York
Agency: New York City DEP DWQC Sample BROOKLYN
Distribution Laboratory
96-05 Horace Harding Ex.
Corona N.Y. 11368 Sample 20350 (NYC DEP)
Dr. Ian Hurley ID of Source:
Received KM Collection 10/2/2001 AT 10:45:00
Bottle C9753,47,289,56,351,138,294,67 Submitted 10/3/2001 AT 11:09:00
Collected By: GERTSIK Sample Type: POT_DW
Comment: PWS No.: Source Code:
Type Descriptor:
Sample chilled on arrival?: YES
Report
Sample No. AD24217
Method Test Description Results Units MDL Analyzed on Validator
bis(2-Ethyihexyl)phthalate 0.78 ug/L 0.60 10/15/2001 DLV
Butachlor <MDL ug/L 0.40 10/15/2001 DLV
EPTC < MDL ug/L 1.0 10/15/2001 DLV
Hexachlorobenzene <MDL ug/L 0.10 10/15/2001 DLV
Hexachlorocyclopentadiene < MDL ug/L 0.10 10/15/2001 DLV
Metolachlor < MDL ug/L 0.75 10/15/2001 DLV
Metribuzin <MDL ug/L 0.15 10/15/2001 DLV
Molinate < MDL ug/L 0.90 10/15/2001 DLV
Simazine < MDL ug/L 0.40 10/15/2001 DLV
Terbacil <MDL ug/L 2.0 10/15/2001 DLV
The recovery for bis(2-Ethylhexyl)phthaIate in the MDL Standard was above its acceptance range. This is probably
due to laboratory contamination.
GCMS Scan For Unknowns
Other unknown compounds ug/L 11/6/2001 DLV
A scan of the extract prepared for the 508 analysis, from 35-550 amu using a mass spectrometer, does not reveal
the presence of non-target compounds. However, 1,2-Dichlorobenzene-d4 is present at 0.30 ug/L, probably due to
laboratory contamination since it is a Surrogate Standard used in GCMS methods.
Stat charge for VOLATILE organic Completed 10/3/2001 12:04 AM SV
Approved Pam Dilsizian QA Officer Date Approved: 11/23/2001
Environmental Laboratories emailed Original 11/23/2001
NYS ELAP # 10108 Page 7 of 7
NYC-WTC_000027224