NYC 9/11 Public Portal Document
REPORT OF ANALYSIS
Westchester County Department of Labs and Research 2 Dana Road Valhalla, New York
gency: New York City DEP DWQC Sample QUEENS
Distribution Laboratory
96-05 Horace Harding Ex.
Corona N.Y. 11368 Sample 42150 DEP LAB#28942
Dr. Ian Hurley ID of Source:
Received KM Collection 9/24/2001 AT 9:29:00
Bottle C51 ,K8044,8050,8051,8661,8584 Submitted 9/25/2001 AT 11:26:00
Collected By: TSUI Sample Type: POT DW
Comment: PWS No.: Source Code:
Type Descriptor:
Sample chilled on arrival? : YES
Report
Sample No. AD23499
Method Test Description Results Units MDL. Analyzed on Validator
Butachlor < MDL ug/L 0.40 10/4/2001 DLV
EPTC < MDL ug/L 1.0 10/4/2001 DLV
Hexachlorobenzene < MDL ug/L 0.10 10/4/2001 DLV
Hexachlorocyclopentadiene < MDL ug/L 0.10 10/4/2001 DLV
Metolachlor < MDL ug/L 0.75 10/4/2001 DLV
Metribuzin < MDL ug/L 0.15 10/4/2001 DLV
Molinate <MDL ug/L 0.90 10/4/2001 DLV
_ Simazine < MDL ug/L 0.07 10/4/2001 DLV
( Terbacil < MDL ug/L 2.0 10/4/2001 DLV
The recoveries for four of the eighteen compounds in the LCS Standard were below their acceptance ranges.
GCMS Scan For Unknowns
Other unknown compounds ug/L 10/19/2001 DLV
A scan of the extract prepared for the 508 analysis, from 35 - 550 arnu using a mass spectrometer, does not reveal
the presence of any non-target compounds generally different than those present in the Laboratory Blank.
Stat charge for VOLATILE organic Completed 9/25/2001 12:01 AM SV
Approved Pam Dilsizian QA Officer Date Approved: 11/1/2001
Environmental Laboratories emailed Original 11/1/2001
NYS ELAP # 10108 Page 7 of7
NYC-WTC_000026639
OCR can misread numbers and units. Confirm readings against the page image before using them.