NYC-WTC_000022902
Reviewed data file listing retention times and response factors for deuterated internal standards.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Reviewed data file listing retention times and response factors for deuterated internal standards.
NYC-WTC_000022780–000022787Folder label: “GCMS X 5/8/02 A 5/10/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Area Percent Report
Data File : C:\HPCHEM\1\DATA\APR2502\9331.D Vial: 8 Acq On : 25 Apr 2002 7:32 pm Operator: Sample : gc/ms scan 4/18 Inst : 209 Mise : Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS0412.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC
peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 8.189 338 342 346 rBV 174632 335824 7.25% 1.446% 2 8.244 346 348 370 rVB 32749 124776 2.69% 0.537% 3 12.210 775 780 793 rBV 1369314 3172444 68.51% 13.659% 4 15.845 1170 1176 1190 rBV 2032412 4072931 87.96% 17.535% 5 21.151 1747 1754 1773 rBV 2172589 4630506 100.00% 19.936%
6 23.281 1980 1986 1991 rBV 159150 308844 6.67% 1.330% 7 25.585 2230 2237 2248 rBV2 2091002 4518364 97.58% 19.453% 8 33.646 3108 3115 3134 rBV2 1507275 3469415 74.93% 14.937% 9 37.869 3566 3575 3593 rBV2 829921 2593778 56.02% 11.167%
Sum of corrected areas: 23226882
9331.D GCMS0412.M Fri Apr 26 08:18:34 2002
NYC-WTC_000022783
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000022902
Reviewed data file listing retention times and response factors for deuterated internal standards.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023754
Laboratory report of GCMS analysis for sample AE09654 conducted on May 23, 2002, showing surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000025533
Fragmented GCMS scan data page showing tentative identification of compounds and surrogate recovery for sample AE10812.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043482
Gas chromatography-mass spectrometry analysis report for sample AE07107 including surrogate compound recovery data.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046351
Laboratory report showing GCMS calibration data for sample AE09334 generated on April 25-26, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045490
Technical document displaying GCMS calibration data and compound retention times for sample AE09448 processed in early May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013277
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045472
Technical document displaying GCMS calibration data and compound retention times for sample AE09447 processed in early May 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043378
Calibration data sheet listing retention times and response factors for deuterated internal standards used in TCLP testing.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011105
Laboratory report showing GC/MS calibration data and surrogate recovery for sample AE03076 on March 22, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045507
Technical document displaying GCMS calibration data and compound retention times for sample AE09449 processed in early May 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022716
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022717
Laboratory form listing GCMS analytical parameters including drip rates, surrogates, and volume measurements.
Filed in the same folder
NYC-WTC_000022719
Laboratory report showing non-detect levels for various volatile organic compounds in a method blank.
Filed in the same folder
NYC-WTC_000022734
Calibration data sheet listing response factors for volatile organic compounds used in GCMS analysis.
Filed in the same folder
NYC-WTC_000022738
Report of reference standard analysis for volatile organic compounds with quantified response values.
Filed in the same folder