Sample: AE07107
Analysis: $524 Volatile Organic Compounds
Units: ug
Started:'3/26/02 00:01 Ended: 3/26/02 00:01 Analyst: BH
Result source: a:\7107.rr
Page: 1
rifa. Component Name’ fViol "h .Result- ' Qualifier MDL.A.
1 P I ha
. 1 Surr- 1,2-DICHLOROETHANE- 5.8 0.5
V :2 Surr - 4-BROMOFLUOROBENZ 4.8 0.5
,* 3. 3 Dichlorodifluoromethane < MDL 0.5
: 4 Chloromethane < MDL 0.5
5‘ Vinyl chloride < MDL 0.5
6, Bromomethane < MDL 0.5
87 Chloroethane < MDL 0.5
8.’Trichlorofluoromethane < MDL — 0.5
19. 1,1-Dichloroethene < MDL 0.5
410 Methylene Chloride < MDL 0.5
11 Methyl tert-butyl ether (MTBE) < MDL To ’
112 trans-1,2-dichloroethene < MDL 0.5
135 1,1-dichloroethane < MDL 0.5
h£ 2-butanone (MEK) < MDL ' 2.0
15*" 2,2-dichloropropane
: .**1
.162 cis-1,2-dichloroethene
< MDL
< MDL
0.5
0.5 REVIEWED BY 4l
*17 *f HM-Chloroform
*18;, Bromochloromethane
< MDL
< MDL
0.5
0.5
DATE 4/5/02
19 1,2-dichloroethane < MDL 0.5
' 20 Surr - TOLUENE-D8 5.2 0.5
212 1,1,1- trichloroethane < MDL 0.5
*22 1,1 -dichloropropene < MDL 0.5
* 23 '^Carbon tetrachloride < MDL 0.5
< MDL
,24-
*25.
Benzene ' 0.5
Trichloroethene < MDL 0.5
: 26 , 1,2-dichloropropane < MDL 0.5
3 27-3 Dibromomethane < MDL 0.5
-28 : *THM-Bromodichloromethane
f* 4
< MDL 0.5
29" Methyl iso-butyl ketone (MIBK) < MDL To
“30., cis-1,3-dichloropropene < MDL 0.5
:31 Toluene < MDL 0.5
32n trans-1,3-dichloropropene
,4
< MDL 0.5
733 > 1,1,2-trichloroethane < MDL 0.5
,34 * Tetrachloroethene < MDL 0.5
35* 1,3-dichloropropane < MDL : 0.5
36—1 *THM-Dibromochloromethane < MDL To
137 Chlorobenzene < MDL 0.5
38, 1,1,1,2-tetrachloroethane < MDL 0.5
r 39 1 Ethylbenzene < MDL 0.5
440: P & M-xylene < MDL 0.5 ”
41 O-xylene < MDL
< MDL
0.5
0.5_______
42 Styrene
-43 1,1,2,2-tetrachloroethane < MDL 0.5
44: *THM-Bromoform < MDL 2.0
645: Isopropylbenzene < MDL 0.5
46______ _
1,2,3-trichloropropane < MDL 0.5
:47. N-propylbenzene < MDL 0.5
448, Bromobenzene < MDL 0.5
NYC-WTC_000022379