Laboratory analysis results for volatile organic compounds sample AE05240 dated March 12, 2002.

NYC-WTC_000021534–000021623

Folder label: “524 3/12/02

Page image
Scanned page image, NYC-WTC_000021616
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (Not Reviewed) Data File : C:\HPCHEM\1\DATA\02MAR12\05240F.D Vial: 24 Acq On : 13 Mar 2002 1:57 am Operator: 201-wb Sample : nyc fb Inst : GC/MS Ins Mise Multiplr: 1.00 MS Integration Params: RTEINT.P Quant Time: Mar 13 2:36 2002 Quant Results File: HP022702.RES Quant Method : C:\HPCHEM\1\METHODS\HP022702.M (RTE Integrator) Title : VOCs BY EPA METHOD 524 Last Update : Mon Mar 11 11:11:58 2002 Response via : Initial Calibration DataAcq Meth : HP022702

Internal Standards R.T. Qlon Response Cone Units Dev(Min) 1) 1,4-DIFLUOROBENZENE 15.09 114 1384794 5.00 ug/L -0.09 24) CHLOROBENZENE-D5 21.74 117 1215759 5.00 ug/L -0.09 52) 1,4-DICHLOROBENZENE-D4 26.92 152 563838 5.00 ug/L -0.09 System Monitoring Compounds 2) 1,2-DICHLOROETHANE-D4 14.32 65 551409 6.16 ug/L -0.09 Spiked Amount 5.000 Recovery = 123.20% 3) 4-BROMOFLUOROBENZENE 24.33 174 443502 3.96 ug/L -0.09 Spiked Amount 5.000 Recovery = 79.20% 25) TOLUENE-D8 18.44 98 1617135 5.52 ug/L -0.09 Spiked Amount 5.000 Recovery = 110.40% Target Compounds Qvalue 12) ACETONE 8.24 43 234212 33.06 ug/L 96 14) METHYLENE CHLORIDE 9.60 49 10332 0.15 ug/L 97 18) 2-BUTANONE (MEK) 12.00 43 1678 0.11 ug/L 60

(#) = qualifier out of range (m) = manual integration 05240F.D HP022702.M Mon Mar 18 15:35:24 2002 Page 1

NYC-WTC_000021616

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000021616Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →