Data File : C:\HPCHEM\l\DATA\02FEB04\0204Bl.D Vial: 1
Acq On : 4 Feb 2002 8:58 am Operator: 201-wb
Sample : lab blank 1 Inst : GC/MS Ins
Mise : February 4, 2002 Multiplr: 1.00
MS Integration Params: LSCINT.P
Quant Method : C:\HPCHEM\1\METHODS\HP013102.M (RTE Integrator)
Title : VOCs BY EPA METHOD 524
Library : C:\DATABASE\NBS75K.L
*********************************************************************
Peak Number 3 2,4-Imidazolidinedione, 3-meth Concentration Rank 2
R.T. EstConc Area Relative to ISTD R.T.
15.81 0.04 ug/L 39256 1,4-DIFLUOROBENZENE 15.15
Hit# of 5 Tentative ID MW MolForm CAS# Qual
1 2,4-Imidazolidinedione, 3-methyl- 114 C4H6N2O2 006843-45-4 3
2 1-(Propenylthio)prop-l-ene 114 C6H10S 000000-00-0 3
3 3-Cyclobutene-1,2-dione, 3,4-dihydr 114 C4H2O4 002892-51-5 2
4 Ethyl diazoacetate 114 C4H6N2O2 000623-73-4 2
Abundance Scan 685 (15.808 min): 0204B1 .D (-) m/z 114.05 100.00%
1 4
5000
63 88 15.40 15.60 15.80 16,00 16.20
.............. 39 ............ 1.................... ...................
[ 1 1 ‘ 1 I ' ' ‘ 1 I ‘ ‘ ' 1 I 1 ‘ 1 1 1 1 1 1 1 I ' ’ 1 1 I 1 1 1 1 I ' ' * ‘ I 1 1 1 ' I 1 m/z 88.1.0 27.90%
m/z—> 20 30 40 50 60 70 80 90 100 110 120
Abundance #64088:2,4-lmidazolidinedione, 3-methyl-
1 4
58
5000 I ' ■ ' ' I ' ■ ' l
15.40 15.60 15.80 16.00 16.20
86 m/z 62.95 23.25%
____________ 42 71
i ■ ■ ■ ■ i ■ ' ■ ■ i ■ ■ ■ ■ i ' ■ i ‘ ■ ■ ■ i ■ ■ ■ ' i ' ■ ■ i 1 ' ■ ' i ■ ■ ■ ■ i ■
m/z—> 20 30 40 50 60 70 80 90 100 110 120
Abundance #2940:1-(Propenylthio)prop-1-ene
41 1 4
99
' 1 i ■ ■ ' ■ i ' '
15.40 15.60 15.80 16.00 16.20
5000 m/ z 49.95 17.25%
59 73 85
47 1
/z—> 20
। * * * * । ■ ■ ■ * । ■ 1
30 40
+1 • i ■ ■ ■ ■ i ■
50 60 70 80 90 100
IIl......I..... 110
' 1 I 1 1
120
Abundance #64087:3-Cyclobutene-1,2-dione, 3,4-dihydroxy-
29 58 15.40 15.60 15.80 16.00 16.20
m/ z 39.05 15.01%
5000 114
■........ I —
41 68 86
i ■ ■ ■ ■ i ■ ' ■ ■ i ■ ■ । । 1 ■ • * । 1 1 * 1 । 1 ■ 1 1 । * * ■ ■ । ■ 1 ■ * । 1 i ■ ■ ■ ■ i ■ ■ IT ■ ■ i ■ ■ ■ ■ i ■ ■
/z—> 20 30 40 50 60 70 80 90 100 110 120 15.40 15.60 15.80 16.00 16.20
0204B1.D HP013102.M Wed Feb 13 10:35:11 2002 Page 3