NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 13/508 Xtract 10/11/01 Analyzed 11/10/11
Document / 10 pages

Pesticide analysis results, sample AD24430, Nov 2001

Machine-extracted title · confidence 95%

Laboratory report listing non-detect results for chlorinated pesticides and PCBs in sample AD24430 analyzed by DEP Labs.

NYC-WTC_000007116–000007125

Folder label: “508 Xtract 10/11/01 Analyzed 11/10/11

Page image
Scanned page image, NYC-WTC_000007117
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed) Signal #1 : C:\HPCHEM\l\DATA\508F\011110\24430.D\ECDlA.CH Vial: 60 Signal #2 : C:\HPCHEM\l\DATA\508F\011110\24430.D\ECD2B.CH Acq On : 12 Nov 2001 10:56 pm Operator: Nefliu Sample : sample Inst : 104 Mise : Multiplr: 1.00 IntFile Signal #1: events.e IntFile Signal #2: events2.e Quant Time: Nov 15 9:27 2001 Quant Results File: 011115T.RES

Quant Method : C:\HPCHEM\1\METHODS\011115T.M (Chemstation Integrator) Title : 508 CHLORINATED PESTICIDES TOXAPHENE7/28/99 Last Update : Fri Nov 09 16:13:01 2001 Response via : Initial Calibration DataAcq Meth : 508F2.M Volume Inj. Signal #1 Phase Signal #2 Phase: Signal #1 Info Signal #2 Info : Compound RT#1 RT#2 Resp#l Resp#2 ug/1 ug/1

System Monitoring Compounds 6) S 2,4-DDD SURROGAT 36.74 33.74 417296 684260 0.090 0.117 # Spiked Amount 0.200 Recovery = 45.00% 58.50% Target Compounds 1) TOXAPHENE PEAK 1 0.00 0.00 0 0 N.D. N.D. d 2) TOXAPHENE PEAK 2 0.00 36.22f 0 5958 N.D. 0.056 # 3) TOXAPHENE PEAK 3 0.00 38.27 0 4385 N.D. 0.057 # 4) TOXAPHENE PEAK 4 0.00 39.25 0 3474 N.D. 0.031 # 5) TOXAPHENE PEAK 5 0.00 0.00 0 0 N.D. N.D. d

(f)=RT Delta > 1/2 Window (#)=Amounts differ by > 25% (m)=manual int. 24430.D 011115T.M Thu Nov 15 09:28:01 2001 Page 1

NYC-WTC_000007117

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000007117Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →