NYC-WTC_000006403
Calibration table listing retention times and responses for deuterated standards including naphthalene-d8.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Initial GCMS analysis report for sample AE01940 conducted by analyst DLV on March 13, 2002.
NYC-WTC_000006371–000006376Folder label: “GCMS X 2/15/02 A 2/9/02 & 2/16/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Report - Integrated Chromatogram
File : C:\HPCHEM\1\DATA\FEB0802\1940.D Operator : 209 GALOS Acquired 9 Feb 2002 3:48 am using AcqMethod GCMS0208 Instrument GC/MS 209 Sample Name: GC/MS SCAN 1/28 Mise Info : Vial Number: 20 Quant File :GCMS0208.RES (RTE Integrator) Abundance TIC: 1940.D 15.99 1200000
1000000 12.35 800000
600000
400000
200000
0- mm.................. ... । . । ................................................. 1, Time-> 6.00 7.00 8.00 9.00 10.00 11.00 J 2.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 Abundance TIC: 1940.D 21.31 25.76 1200000
1000000
800000
600000
400000
200000 30.83
Time-s 20.00 21.00 22.00 23.00 24.00 25.00 26.00 27.00 28.00 29.00 30.00 L 31.00 .32.00 33.00 Abundance .. TIC: 1940.D
1200000
1000000 .83 800000
600000 38.12 400000
200000
0—— Time-> 34.00 35.00 36.00 37.00 38.00 39.00 40.00 41.00 42.00 43.00 44.00 45.00 46.00 47.00
1940.D GCMS0208.M Fri Mar 08 15:29:02 2002
NYC-WTC_000006375
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000006403
Calibration table listing retention times and responses for deuterated standards including naphthalene-d8.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000006387
Calibration table listing retention times and responses for deuterated standards including naphthalene-d8.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052600
Calibration record for GC/MS instrument 209 used in TCLP testing, listing standard compounds and response factors from February 14, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052666
Calibration record for GC/MS instrument 209 used in TCLP testing, listing standard compounds and response factors from February 14, 2002.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052614
Calibration record for GC/MS instrument 209 used in TCLP testing, listing standard compounds and response factors from February 14, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052736
GC/MS analysis report for sample AE01037 showing surrogate recovery data generated on February 26, 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009686
Laboratory file showing GC/MS calibration response factors for surrogate compounds from February and March 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052714
Calibration table and instrument data for GC/MS analysis generated on February 12 and 19, 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052586
Calibration record for GC/MS instrument 209 used in TCLP testing, listing standard compounds and response factors from February 14, 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052701
Calibration record for GC/MS instrument 209 used in TCLP testing, listing standard compounds and response factors from February 14, 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009670
Laboratory file showing GC/MS calibration response factors for surrogate compounds from February and March 2002.
1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052630
Calibration record for GC/MS instrument 209 used in TCLP testing, listing standard compounds and response factors from February 14, 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000003856
Laboratory report for sample AE01939 showing GCMS analysis of unknown compounds and surrogate recovery on February 15, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009794
Analytical results page for sample AE01233 processed on February 25, 2002, showing surrogate recovery data.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009764
Analytical results page for sample AE01230 processed on February 25, 2002, showing surrogate recovery data.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052936
Laboratory report documenting gas chromatography-mass spectrometry analysis of sample AE01405 conducted on February 27, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000005660
Laboratory report for DEP sample AE02969 showing unknown compounds and surrogate recovery data from February 15, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009721
Analytical results page for sample AE01220 processed on February 25, 2002, showing surrogate recovery data.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000006359
Department of Environmental Protection GCMS sample tracking record for the World Trade Center site dated February 2002.
Filed in the same folder
Header page for a GCMS log sheet covering the period from February 15 to March 2, 2002.
Filed in the same folder
NYC-WTC_000006362
Initial GCMS analysis report for sample AE01940 conducted by analyst DLV on March 13, 2002.
Filed in the same folder
NYC-WTC_000006377
Quality control page documenting surrogate compound recovery rates for a gas chromatography mass spectrometry run.
Filed in the same folder
NYC-WTC_000006387
Calibration table listing retention times and responses for deuterated standards including naphthalene-d8.
Filed in the same folder