NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 12/GCMS X 2/12/02 A 3/01/02
Document / 20 pages

GCMS analysis results for sample AE03252, March 2002

Machine-extracted title · confidence 95%

Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE03252 conducted on March 15, 2002.

NYC-WTC_000006226–000006245

Folder label: “GCMS X 2/12/02 A 3/01/02

Page image
Scanned page image, NYC-WTC_000006245
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Operator ID: Date Acquired: 1 Mar 2002 8:57 pm ata File: C:\MSDCHEM\l\5973N\02MAR01\03252.D ame: 508 scan isc: March 1, 2002 Method: C:\MSDCHEM\1\METHODS\METHODS\HP022102.M (RTE Integrator) Title: 508 scan method Library Searched: C:\DATABASE\WILEY7N.L

--Internal Standard-- TIC Top Hit name RT EstConc Units Response # RT Resp Cone Butanoic acid, /me. . 3.62 0.1 ug/L 50744 1 9.71 9135850 20.0 2-Buten-l-ol, B-m. . 4.65 0.1 ug/L 46251 1 9.71 9135850 20.0 2-Butenal, 3-meth.. 4.86 0.1 ug/L 65179 1 9.71 9135850 20.0 Acetic acid, j3- [1. - 5.89 4.3 ug/L 1943680 1 9.71 9135850 20.0 Zyclopentasiloxan. . 12.54 0.1 ug/L 79551 2 13.20 13255200 20.0 2 - Me t hoxy - 3- hydra.. 13.38 0.0 ug/L 31599 2 13.20 13255200 20.0 4H-Pyran-4 - one , 2 . . 16.55 0.1 ug/L 39417 3 18.33 14486300 20.0 -perdeuteriobenz . . 22.28 0.1 ug/L 101994 4 22.63 15486000 20.0 DECADEUTEROPHENAN. . 22.77 0.5 ug/L 358802 4 22.63 15486000 20.0 3,6-Dimethyl-tria.. 24.85 0.0 ug/L 27223 4 22.63 15486000 20.0 l-Octadecarol ‘A. . 26.18 0.0 ug/L 33218 4 22.63 15486000 20.0 Dctadecane, 1- (et. . 28.49 0.1 ug/L 41462 5 30.49 13641200 20.0 1,2-Benzenedicarb. . 31.10 0.1 ug/L 78383 5 30.49 13641200 20.0

33252.D HP022102.M Mon Mar 04 12:33:56 2002 Page 16

NYC-WTC_000006245

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000006245Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →