NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 12/GCMS X 2/12/02 A 3/01/02
Document / 20 pages

GCMS analysis results for sample AE03251, March 2002

Machine-extracted title · confidence 95%

Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE03251 conducted on March 15, 2002.

NYC-WTC_000006206–000006225

Folder label: “GCMS X 2/12/02 A 3/01/02

Page image
Scanned page image, NYC-WTC_000006225
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document * * ‘• — Li - t Ll U t LUA — y

Operator ID: Date Acquired: 1 Mar 2002 8:07 pm Data File: C:\MSDCHEM\1\5973N\02MAR01\03251.D Name: 508 scan Mise: March 1, 2002 Method: C:\MSDCHEM\1\METHODS\METHODS\HP022102.M (RTE Integrator) Title: 508 scan method Library Searched: C.: \DATABASE\WILEY7N.L

--Internal Standard-- TIG Top Hit name RT EstConc Units Response # RT Resp Cone Butanoic acid,/me. 3.61 0.1 ug/L 47284 1 9.71 8324370 20.0 Propane, 1,1 - dime . 3.92 0.1 ug/L 26230 1 9.71 8324370 20.0 ETHYLENE DIAMMONI . 4.25 0.1 ug/L 31518 1 9.71 8324370 20.0 2-Propenamide $$ . 4.65 0.1 ug/L 33577 1 9.71 8324370 20.0 2H-Pyran,\ :3/4-dih. 4.86 0.1 ug/L 54828 1 9.71 8324370 20.0 2 -FuranmetHanoi, . 5.01 0.2 ug/L 70252 1 9.71 8324370 20.0 CIS-1-METH OXY-2-B. 5.71 0.1 ug/L 34860 1 9.71 8324370 20.0 3- (CYCLOHE X-3‘ -EN. 5.89 3.7 ug/L 1533000 1 9.71 8324370 20.0 Cyclopenta:siloxan . 12.54 0.3 ug/L 152078 2 13.20 12136400 20.0 2-Methoxy^3 -hydra. 13.38 0.1 ug/L 36559 2 13.20 12136400 20.0 Decanal (CAS) $ - 13.58 0.1 ug/L 41010 2 13.20 12136400 20.0 1,2- Pheny .ene dii . . 22.28 0.1 ug/L 86828 4 22.63 13350300 20.0 1,2 -Benze: edicarb . . 31.09 0.0 ug/L 27873 5 30.49 11884500 20.0

)3251.D HP022102.M Mon Mar 04 12:33:49 2002 Page 16

NYC-WTC_000006225

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000006225Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →