NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\1\DATA\FEB0802\31136.D Vial: 41
Acq On : 10 Feb 2002 12:09 am Operator: 209 GALOS
Sample : RE-EXTRACT 2/7 FB Inst : GC/MS 209
Mise : Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Feb 13 10:57 2002 Quant Results File: GCMS0208.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0208.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Fri Feb 08 15:29:22 2002
Response via : Initial Calibration
DataAcq Meth : GCMS0208
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4 -Dichlorobenzene-d4 12.35 152 370465 20.00 ug/1 0.00
10) Naphthalene-d8 15.99 136 1436133 20.00 ug/1 0.00
17) Acenaphthene-diO 21.31 164 768869 20.00 ug/1 0.00
29) Phenanthrene-diO 25.75 188 1109418 20.00 ug/1 -0.01
38) Chrysene-dl2 33.82 240 714187 20.00 ug/1 -0.02
44) Perylene-dl2 38.11 264 438242 20.00 ug/1 -0.01
System Monitoring Compounds
37) 2,4-DDD 30.83 235 51311 3.72 ug/mL 0.33
Spiked Amount 5.000 Recovery = 74.40%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 0.00 74 0 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2'-oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 0.00 128 0 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 0.00 165 0 N.D.
25) Diethylphthalate 22.78 149 9860 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
31136.D GCMS0208.M Wed Feb 13 10:58:00 2002 Page 1
NYC-WTC_000005736
OCR can misread numbers and units. Confirm readings against the page image before using them.